Help with SLO100
Hey Guys!
Creating another post since it seems like the forum has been more active. I have a dead SLO 100 on my bench that has been languishing for over a year. Here's what is going on:
Amp powers up, relays work, all tubes glow and get expected voltage. Bias circuit works. After some time (approximately 30 seconds to one minute), the current limiter bulb slowly grows in brightness until it is BRIGHT, and at the same time, the indicator LEDs for the amp's channels dim.
I'm using the recommended power transformer. This problem only happens when the power tubes are installed, and I've checked the power tube pins and circuit a million times.
Any help would be wildly appreciated. Dr. Andrea? Thanks!


Could be several things. The 30 to 60 second delay on the current limiter getting brighter suggests that you may have one or more bad power tubes, as it takes about that long for the tubes to reach full operating temperature and the power transformer reaching full plate/screen DC voltage under load. You can test by installing pairs and seeing which pair produces the same issue (V5/V8 - outside pair, then V6/V7 - inside pair). If you do this, halve the speaker impedance: if your running an 8 ohm cab, change to 4 ohm or if 16 ohm, then 8 ohm.
Parasitic oscillation - if lead dress or power-section ground paths are slightly compromised, it can drive the power tubes into maximum current conduction without making any audible sound through the speaker. Verification is best done with a scope, but you can check lead dress around the power tube grid stoppers (pins 5) and screen resistors (pins 4).
Screen grid resistor(s) - A screen grid resistor (on pin 4) breaking down or a screen/plate wire positioned too close to a ground lug/chassis. Check screen grid resistors for burning or cracking. Measure resistance from screen grid nodes to ground with the amp off and caps drained.
Less likely, unless you noticed red plating, but a failing coupling capacitor coming off the phase inverter (V4) can leak DC voltage onto the power tube grids (Pin 5) only after warming up. Positive DC voltage on the grids overrides negative bias, causing immediate thermal runaway. Check by CAREFULLY measuring the DC voltage directly at Pin 5 of each power tube socket during the 30-to-60-second warmup. If the negative bias voltage drops toward 0V DC (or goes positive), replace the phase inverter output coupling capacitors.
Hopefully, it's just a failing power tube (easiest fix).